kb:labview:automation
Table of Contents
09 Automation
Headless Execution
LabVIEW 2026 Q1 introduced native headless execution by adding the call parameter --headless (or -headless for LabVIEW-CLI)
Suppressing Popups
Use the following INI tokens (LabVIEW.ini) to suppress popups and auto-reporting errors:
# Error reporting NIERShowFatalDialog=0 NIERFatalAutoSend=true NIERNonFatalAutoSend=true NIERShowNonFatalDialogOnExit=false NIERSendDialogClose=true # Warnings and error handling autoerr=3 DWarnDialog=false promoteDWarnInternals=false ShowAIVIsInErrorWindow=true # Automation AutoSaveEnabled=false AllowMultipleInstances=true # Additional candidates - validate first suppressFileDlgForMissingVIs=TRUE skipNavigatorDialog=TRUE defaultErrorHandlingForNewVIs=False EnableAutomaticErrorHandling=False
Taken in parts from Best Practices on How to Use LabVIEW with Jenkins Continuous Integration and LabVIEW for Containers
Unattended Mode
LabVIEW features an internal Application property called Unattended Mode. Its purpose is to prevent LabVIEW from displaying prompts to save modified VIs when closing the development environment.
Note: Reading this property node can help with detecting if LabVIEW was executed via its CLI (Source: Raph Schru on Discord).
Property
kb/labview/automation.txt · Last modified: by joerg.hampel